![CONTROL SAFEX-C.12-11N1-2N.01-NN-NN [R911175242]](iblock/b0b/dbpq9txtnw7b34f1umq3iwozy5e70lh0.jpg)
CONTROL SAFEX-C.12-11N1-2N.01-NN-NN [R911175242]
Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.
- Проверка производителя
- Безналичная оплата
- Доставка по России
- Подбор аналога
Описание
SAFEX-C.12 Safe Control; 16 channels. Safe Dig. Input 24V; 6 channels. Safe Dig. Output 24V, 0.5A; 4 channels. Dig Output 24V, 2.0A; 2 channels. Safe Relay Output Product Description ctrlX SAFETY – SAFEX-C.12 – Compact safety controller (16 inputs, 12 outputs, 2 relay outputs) optimized for the smallest installation space in the control cabinet, compact machinery by rapid response via local I\/O with reliable control of ctrlX DRIVE via ctrlX SAFETYlink and safe integration into any EtherCAT network (FSoE-Master and slave) Technical Specs Product attributes ctrlX Configurator https://www.boschrexroth.com/ctrlx-configurator/#/solution/?m=R911175242 EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.SAFEX-C.12-11N1-2N.01-NN-NN**&downloads=true Number of channels 16 Width [mm] 61 Height [mm] 105 Depth [mm] 85 International protection code IP20 Protection class III Maximum permitted voltage range [V DC] 18-31.2 Power consumption Idle: Max. 350 mA (DC 24 V); full load: Max. 350 mA + 8 A (outputs) (DC 24 V) Type of interface 1 × USB host, TYPE C (USB 2.0),RJ45 (IN XF28, OUT XF29): EtherCAT (CoE, EoE, FSoE), SMMC Number of pulse sources 2 Pulse length (input test) Typisch 0,25 ms (max. 0,5 ms) Pulse length (external, tolerated) Max. 0,5 ms Number of safe relay outputs (single-channel) 2 (x2 Kontakte) Maximum number of FSoE slave devices Bis zu 32 (max. 256 Bytes pro Richtung); Max. 12 Achsen Safety integrity level SIL 3 (IEC 61508) Proof test interval 20 years= max. service life PFH / architecture Category 4 Performance level PL e (EN ISO 13849-1) Fuse protection (UP) 8 A (4 A in the cULus scope) Fuse protection (UL) 5 A Current requirement UL 350 mA Current requirement Up 8 A (4 A in the cULus scope) Nominal voltage (UL/UP) DC 24 V (-10%, +20%), supply type (SELV/PELV); for UL-conformity DC 24 V (-10%, +10%) Permissible air humidity (storage) [%] 8-95 Permissible air humidity (transport) [%] 5-95 Ambient temperature for transport [°C] -25-70 Ambient temperature storage [°C] -40-70 Ambient temperature during operation Up to 3,000 m: 0 °C to +50 °C; for UL compliance 0° to +45°C Maximum operating altitude [m] 3000 Contamination level 2 according to DIN EN 60664-1:2007 Weight [kg] 0.49