Промышленные компоненты для предприятий России
BBREZGIndustrial Group
FIELD BUS MODULE XB-EC-12 [R911406090]
REXROTH

FIELD BUS MODULE XB-EC-12 [R911406090]

Артикул  /  R911406090
Коммерческое предложение

Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.

  • Проверка производителя
  • Безналичная оплата
  • Доставка по России
  • Подбор аналога
О позиции

Описание

ctrlX I/O EtherCAT bus coupler Product Description The bus coupler XB-EC-12 connects the EtherCAT network and the ctrlX I\/O system. It supplies the connected I\/O modules with the logic voltage UL and peripheral voltage UP. The voltages and currents fed in are measured internally and applied to the process data. For the integration into the parent system, the respective ESI files are available. These files are available for download at www.boschrexroth.com\/electrics. Technical Specs Product attributes EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XB-EC-12**&downloads=true Connection type Push-in Width [mm] 23.3 Height [mm] 105 Depth [mm] 99 International protection code IP20 Protection class III Backplane-Bus Standard-EtherCAT über LVDS EMC resistance EN 61000-6-2 and EN 61000-6-4 Bit width, input data in the process data image (including fill bits) 10 bytes Maximum power dissipation in the module [W] 2.64 Inverse polarity protection up to [V] 50 Channel LEDs Display status of Power supply Post-assembly position Vertical, on a horizontal support rail Electrical isolation 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) Fuse protection (UP) No internal fuse protection. The operator has to provide protection against overload by an external fuse. Fuse protection (UL) Internal with a protective fuse Transient protection Present, suppressor diodes, pulse load up to 1500 W Maximum number of modules per station 30 Power input UP Typ. 0.12 W (without I/O modules), 192 W max. (complete system with I/O modules) Power input UL 1.64 W max. (without I/O modules), 72 W max. (complete system with I/O modules) Current requirement UL Max. 60 mA (without I/O modules), 3 A max. (complete system with I/O modules) Current requirement Up Typ. 7 mA (without I/O modules), 8 A max. (complete system with I/O modules) Nominal voltage (UL/UP) DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) Overvoltage category 2 Voltage dips at power supply interfaces PS1 <1 ms, evaluation criterion A Overvoltage protection UL and UP Present, fuses can trigger in case of overvoltage Supply voltage LEDs At the connection point to signal the applied voltage Conductor cross-section rigid: 0.75-1.5 mm²,Flexible: 0.75-1.5 mm²,AWG: 18 ... 16 Permissible air humidity (storage) [%] 10-95 Permissible air humidity (transport) [%] 10-95 Ambient temperature (storage and transport) [°C] -40-70 Ambient temperature during operation Up to 2,000 m: -25 °C to +55 °C,2,000 m to 3,000 m: -25 °C to +50 °C,3,000 m to 4,000 m: -25 °C to +45 °C,4,000 m to 5,000 m: -25 °C to +40 °C Maximum operating altitude [m] 5000 Contamination level 2, no condensation Weight [kg] 0.19