Промышленные компоненты для предприятий России
BBREZGIndustrial Group
FEED MODULE XI811101 [R911406093]
REXROTH

FEED MODULE XI811101 [R911406093]

Артикул  /  R911406093
Коммерческое предложение

Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.

  • Проверка производителя
  • Безналичная оплата
  • Доставка по России
  • Подбор аналога
О позиции

Описание

ctrlX I/O passive voltage supply terminal for the periphery circuit (UP) DC 24 V / 8A. Product Description The XI811101 passive voltage power feeding module is used to feed in the peripheral circuitry (UP) again in a ctrlX I\/O station. It supplies the connected I\/O modules with peripheral voltage (UP) with DC 24 V, 8A. The module is designed without state display on a removable periphery plug and is not a device in the local bus. The logic voltage supply as well as the EtherCAT-based module communication are routed through the module. Technical Specs Product attributes EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XI811101**&downloads=true Connection type Push-in Width [mm] 20 Height [mm] 105 Depth [mm] 99 International protection code IP20 Protection class III Backplane-Bus Standard-EtherCAT über LVDS EMC resistance EN 61000-6-2 and EN 61000-6-4 Inverse polarity protection up to [V] 50 Channel LEDs Display status of Power supply Post-assembly position Vertical, on a horizontal support rail Electrical isolation 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) Fuse protection (UP) No internal fuse protection. The operator has to provide protection against overload by an external fuse. Transient protection Present, suppressor diodes, pulse load up to 1500 W Maximum number of modules per station 30 Current requirement Up Typ. 0.024 mA (without I/O modules), 8 A max. (complete system with I/O modules) Nominal voltage (UL/UP) DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) Overvoltage category 2 Voltage dips at power supply interfaces PS1 <1 ms, evaluation criterion A Overvoltage protection UL and UP Present, external fuses can trigger in case of overvoltage Conductor cross-section rigid: 0.2-1.5 mm²,Flexible: 0.2-1.5 mm²,AWG: 24 ... 16 Permissible air humidity (storage) [%] 10-95 Permissible air humidity (transport) [%] 10-95 Ambient temperature (storage and transport) [°C] -40-70 Ambient temperature during operation Up to 2,000 m: -25 °C to +55 °C,2,000 m to 3,000 m: -25 °C to +50 °C,3,000 m to 4,000 m: -25 °C to +45 °C,4,000 m to 5,000 m: -25 °C to +40 °C Maximum operating altitude [m] 5000 Contamination level 2, no condensation Weight [kg] 0.12