![FUNCTIONAL MODULE XI141202 [R911421639]](iblock/a9c/ns36nsa7k0b273yb46fqxvbqizjihvhz.jpg)
FUNCTIONAL MODULE XI141202 [R911421639]
Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.
- Проверка производителя
- Безналичная оплата
- Доставка по России
- Подбор аналога
Описание
ctrlX I/O 2-channel counter terminal 10 kHz (24 VDC), 2-wire Product Description The digital input module XI141202 is an up and down counter (32 bit) and used to detect binary 24 V control signals in a ctrlX I\/O station. The module is designed with two separate counters, each with its own control input. This control input determines the counter direction or is used as Gate input. The two outputs are switched depending on the counter reading and can be used as fast control signals. The signal state of the inputs and outputs is shown at the channel LED on the removable peripheral plug. The logic and peripheral supply as well as the EtherCAT-based module communication are routed through the module. Technical Specs Product attributes EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XI141202**&downloads=true Connection type Push-in Connectivity technology 2-wire technique Number of channels 2 Max. output current per channel [A] 0.5 Width [mm] 12 Height [mm] 105 Depth [mm] 99 International protection code IP20 Protection class III Backplane-Bus Standard-EtherCAT über LVDS EMC resistance EN 61000-6-2 and EN 61000-6-4 Bit width, output data in the process data image 4 Bytes Bit width, input data in the process data image (including fill bits) 14 bytes Maximum power dissipation in the module [W] 1.95 Input filter user selectable (25, 100, 500, 1000, 3000) Inductive switch-off energy Max. 150 mJ Inverse polarity protection up to [V] 30 Nominal load [Ohm] 48 Fuse protection (UOUT24 V) Internal with a protective fuse Channel LEDs Per channel Post-assembly position Vertical, on a horizontal support rail Electrical isolation 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) Rise time (TRise) 29 µs Fall time (TFALL) 19 µs Feedback voltage resistance Not resistant to feedback, external measures required Current requirement UL 35 mA Current requirement Up 36 mA + load Max. current up per terminal point [A] 1 Max. net current Up module [A] 2 Net current module outputs [A] 1 Input current [mA] 2.4 Signal voltage "0" [V] -3-5 Signal voltage "1" [V] 11-30 Nominal voltage (UL/UP) DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) Overvoltage category 2 Nominal output voltage [V DC] 24 Nominal input voltage [V DC] 24 Conductor cross-section rigid: 0.2-1.5 mm²,Flexible: 0.2-1.5 mm²,AWG: 24 ... 16 Overload protection pulse operation for outputs, N/A for inputs Permissible air humidity (storage) [%] 10-95 Permissible air humidity (transport) [%] 10-95 Ambient temperature (storage and transport) [°C] -40-70 Ambient temperature during operation Up to 2,000 m: -25 °C to +55 °C,2,000 m to 3,000 m: -25 °C to +50 °C,3,000 m to 4,000 m: -25 °C to +45 °C,4,000 m to 5,000 m: -25 °C to +40 °C Maximum operating altitude [m] 5000 Contamination level 2, no condensation Weight [kg] 0.11