![FUNCTIONAL MODULE XI241202 [R911421644]](iblock/794/bhk6nlkgtnay0pwjf28ld49pkamgwous.jpg)
FUNCTIONAL MODULE XI241202 [R911421644]
Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.
- Проверка производителя
- Безналичная оплата
- Доставка по России
- Подбор аналога
Описание
ctrlX I/O 2-channel pulse width modulation (PWM) output terminal (DC 24 V, 0.5 A), 2-wire Product Description The digital output module XI241202 is used to output pulse-width-modulated binary 24 V control signals in a ctrlX I\/O station. It has two channels in a 2-wire technique. The signal state is shown at the channel LED on the removable peripheral connector. The parent control specifies the clock and pulse\/pause ratio. The digital outputs are fed via the 24 V supply from UP. The logic and peripheral voltage supply as well as the EtherCAT-based module communication are routed through the module. Technical Specs Product attributes EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XI241202**&downloads=true Connection type Push-in Connectivity technology 2-wire technique Number of channels 2 Max. output current per channel [A] 0.5 Width [mm] 12 Height [mm] 105 Depth [mm] 99 International protection code IP20 Protection class III Backplane-Bus Standard-EtherCAT über LVDS EMC resistance EN 61000-6-2 and EN 61000-6-4 Bit width, output data in the process data image 12 Bytes Bit width, input data in the process data image (including fill bits) 6 bytes Maximum current fed into all GND Output Pins of the module [A] 1 Maximum power dissipation in the module [W] 1.805 Maximum current fed into one GND Output Pin [A] 0.5 Inductive switch-off energy Max. 150 mJ Nominal load [Ohm] 48 Channel LEDs Per channel Post-assembly position Vertical, on a horizontal support rail Electrical isolation 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) Rise time (TRise) 0.33 µs Fall time (TFALL) 0.3 µs Feedback voltage resistance Not resistant to feedback, external measures required Current requirement UL 35 mA Current requirement Up 1.05 mA Net current module outputs [A] 1 Nominal voltage (UL/UP) DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) Overvoltage category 2 Nominal output voltage [V DC] 24 Conductor cross-section rigid: 0.2-1.5 mm²,Flexible: 0.2-1.5 mm²,AWG: 24 ... 16 Overload protection Granular switch-off with automatic restart Permissible air humidity (storage) [%] 10-95 Permissible air humidity (transport) [%] 10-95 Ambient temperature (storage and transport) [°C] -40-70 Ambient temperature during operation Up to 2,000 m: -25 °C to +55 °C,2,000 m to 3,000 m: -25 °C to +50 °C,3,000 m to 4,000 m: -25 °C to +45 °C,4,000 m to 5,000 m: -25 °C to +40 °C Maximum operating altitude [m] 5000 Contamination level 2, no condensation Weight [kg] 0.11