![FUNCTIONAL MODULE XI614001 [R912009619]](iblock/da5/85jbl0hy5u8o9xiifauo1vfw82nu8klj.jpg)
FUNCTIONAL MODULE XI614001 [R912009619]
Сообщим стоимость, доступное количество и срок поставки. Если точной позиции нет, предложим проверенный аналог.
- Проверка производителя
- Безналичная оплата
- Доставка по России
- Подбор аналога
Описание
ctrlX I/O 1-channel Encoder Interface SSI Product Description The XI614001 encoder module enables the connection of an absolute encoder with SSI (synchronous serial interface) in a ctrlX I\/O station. Both singleturn and multiturn encoders are supported. The 24 V encoder supply can be provided directly via the module's connection points. The four additional digital inputs, which are designed in 2-wire technology, enable the connection of application-specific signals. The logic and peripheral voltage supply as well as the EtherCAT-based module communication are routed through the module. Technical Specs Product attributes EPLAN https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XI614001**&downloads=true Connection type Push-in Connectivity technology Differential RS422 Number of channels 1 Width [mm] 12 Height [mm] 105 Depth [mm] 99 International protection code IP20 Protection class III Backplane-Bus Standard-EtherCAT über LVDS EMC resistance EN 61000-6-2 and EN 61000-6-4 Bit width, output data in the process data image 2 Bytes Bit width, input data in the process data image (including fill bits) 12 bytes Maximum power dissipation in the module [W] 1.79 Input filter 3 ms Fuse protection (UOUT24 V) Auto switch-off at overload Channel LEDs Per channel Post-assembly position Vertical, on a horizontal support rail Electrical isolation 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) Current requirement UL 0.037 Current requirement Up 0.03 A + load Max. current up per terminal point [A] 1 Max. net current Up module [A] 3 Input current [mA] 3.6 Signal voltage "0" [V] -3-5 Signal voltage "1" [V] 15-30 Nominal voltage (UL/UP) DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) Overvoltage category 2 Nominal input voltage [V DC] 24 Signal type SSI Encoder Conductor cross-section rigid: 0.2-1.5 mm²,Flexible: 0.2-1.5 mm²,AWG: 24 ... 16 Overload protection Fuse switch-off at overload Permissible air humidity (storage) [%] 10-95 Permissible air humidity (transport) [%] 10-95 Ambient temperature (storage and transport) [°C] -40-70 Ambient temperature during operation Up to 2,000 m: -25 °C to +45 °C,2,000 m to 3,000 m: -25 °C to +45 °C Maximum operating altitude [m] 3000 Contamination level 2, no condensation Weight [kg] 0.12